Intel Cyclone 10 GX Device Errata and Design Guidelines
1. Intel Cyclone 10 GX Device Errata
Issue | Affected Devices | Planned Fix |
---|---|---|
Automatic Lane Polarity Inversion for PCIe Hard IP | All Intel® Cyclone® 10 GX devices | No planned fix |
High VCCBAT Current when VCC is Powered Down | All Intel® Cyclone® 10 GX devices | No planned fix |
Failure on Row Y59 When Using the Error Detection Cyclic Redundancy Check (EDCRC) or Partial Reconfiguration (PR) |
|
No planned fix |
1.1. Automatic Lane Polarity Inversion for PCIe Hard IP
For Intel® Cyclone® 10 GX PCIe Hard IP open systems where you do not control both ends of the PCIe link, Intel does not guarantee automatic lane polarity inversion with the Gen1x1 configuration, Configuration via Protocol (CvP), or Autonomous Hard IP mode. The link may not train successfully, or it may train to a smaller width than expected. There is no planned workaround or fix.
For all other configurations, refer to the following workaround.
Workaround
Refer to the Knowledge Database in the related links below for details to workaround this issue.
Status
Affects: Intel® Cyclone® 10 GX devices.
Status: No planned fix.
1.2. High VCCBAT Current when VCC is Powered Down
If you power off VCC when VCCBAT remains powered on, VCCBAT may draw higher current than expected.
If you use the battery to maintain volatile security keys when the system is not powered up, VCCBAT current could be up to 120 µA, resulting in shortened battery life.
Workaround
Contact your battery provider to evaluate the impact to the retention period of the battery used on your board.
There is no impact if you connect the VCCBAT to the on-board power rail.
Status
Affects: Intel® Cyclone® 10 GX devices
Status: No planned fix.
1.3. Failure on Row Y59 When Using the Error Detection Cyclic Redundancy Check (EDCRC) or Partial Reconfiguration (PR)
When the error detection cyclic redundancy check (EDCRC) or partial reconfiguration (PR) feature is enabled, you may encounter unexpected output from clocked components such as flip-flop or DSP or M20K or LUTRAM that are placed at row 59 in Intel® Cyclone® 10 GX devices.
This failure is sensitive to temperature and voltage.
- In
Intel®
Quartus® Prime Standard Edition:
- Info (20411): EDCRC usage detected. To ensure reliable operation of these features on the targeted device, certain device resources must be disabled.
- Error (20412): You must create a floorplan assignment to block out the device resources at row Y=59 and ensure reliable operation with EDCRC. Use the Logic Lock (Standard) Regions Window to create an empty reserved region with origin X0_Y59, height = 1 and width = <#>. Also, review any existing Logic Lock (Standard) regions that overlap that row and ensure if they account for the unused device resources.
- In
Intel®
Quartus® Prime Pro Edition:
- Info (20411): PR and/or EDCRC usage detected. To ensure reliable operation of these features on the targeted device, certain device resources must be disabled.
- Error (20412): You must create a floorplan assignment to block out the device resources at row Y=59 and ensure reliable operation with PR and/or EDCRC. Use the Logic Lock Regions Window to create an empty reserved region, or add set_instance_assignment -name EMPTY_PLACE_REGION "X0 Y59 X<#> Y59-R:C-empty_region" -to | directly to your Quartus Settings File (.qsf). Also, review any existing Logic Lock regions that overlap that row and ensure if they account for the unused device resources.
Workaround
Apply the empty logic lock region instance in the Quartus Prime Settings File (.qsf) to avoid use of row Y59. For more information, refer to the corresponding knowledge base.
Status
- Intel® Cyclone® 10 GX 085 devices
- Intel® Cyclone® 10 GX 105 devices
- Intel® Cyclone® 10 GX 150 devices
- Intel® Cyclone® 10 GX 220 devices
Status: No planned fix.
2. Document Revision History for Intel Cyclone 10 GX Device Errata and Design Guidelines
Document Version | Changes |
---|---|
2020.01.10 | Added a new erratum: Failure on Row Y59 When Using the Error Detection Cyclic Redundancy Check (EDCRC) or Partial Reconfiguration (PR). |
2017.11.06 | Initial release. |